Variable ID
              RELH
          Variable Type
              Standard - Primary
          Variable Category
              Moisture
          Standard Units
              percentage
          Description
              The 5-minute average relative humidity at a height of 1.5 meters above the ground. Because of the sorption sensor's inherent inaccuracy at saturation, the mesonet restricts all readings above 100% to 100%.
- Relative humidity changes when either the moisture content of the air or the air temperature changes.
Accuracy
          ± 3% for 10–98%
              Sensors
          Vaisala HMP155 (2015–present)
          Vaisala HMP45C (1994–2015)
              Documentation Links
          
      Sensor Image URL
              https://content.prod.mesonet.org/repos/instruments/images/vaisala-hmp155.jpg
          Sensor Image Alt Text
              Vaisala HMP155
          Sensor Image Caption
              Vaisala HMP155